-40%

Protection Relay Tester Current 3Phase Microcomputer Secondary Current Injection

$ 1237.44

Availability: 18 in stock
  • Condition: New
  • Three-Phase Parallel Output: 0-120A
  • Measuring Voltage Range: 110V (1A) -220V (0.6A)
  • Output Voltages: 110V (1A) -220V (0.6A)
  • Switching Input Terminal: 8 Pairs
  • Plug Type: UK
  • DC Current Output: 0- ± 10A/Phase,Accuracy: 0.5% ± 5mA
  • The voltage load: Cannot exceed 70W,otherwise it will open circuit protection
  • Current Source: AC/DC Voltage Source,AC/DC Current Source
  • AC Single Phase Current Output: 0-40A/Phase,Accuracy: 0.2% ± 5mA
  • Measuring Current Range: 0 - ± 10 A / phase
  • Brand: VLUUKE
  • Phase Voltage/Line Voltage Output Power: 70va/90va

    Description

    Product Interview:
    1.Windows XP operation interface, high-performance embedded industrial control computer, easy and fast operation.
    2.It has software self-calibration function, which greatly improves the accuracy and stability.
    3.The power amplifier adopts high-fidelity linear power amplifier, which not only ensures the accuracy of small current, but also ensures the stability of large current.
    4.It adopts USB interface to communicate with PC directly, without any adapter cable, which is convenient to use.
    5.The main control board adopts DSP+FPGA structure and 16-bit DAC output, which can generate 2000 high-density sine waves per week for the fundamental wave, which greatly improves the quality of the waveform and the accuracy of the tester.
    Main Features:
    (1)Current source : AC/DC voltage source, AC/DC current source
    (2)Parallel Output:Three-phase parallel output (effective value):  0-90A
    (3)Max Output Power Per Phase:400 VA
    (4)Frequency Range:0 ~ 1000 Hz, accuracy 0.01 Hz
    (5)Switch Input Terminal:8 pairs
    (6)Harmonic Number:Harmonic Number
    (7)Phase:0 ~360,The accuracy is 0.1 degree
    (8)DC Current Output:0 ~ ± 10 A / phase, accuracy: 0.2 % ± 5 mA
    (9)Dimensions:410 mm * 190 mm * 420 mm
    (10)Time range : 1ms -9999s
    (11)Measurement accuracy : 1ms
    (12)Weight:12.5 kg
    Parameters:
    Model
    LND-802
    Output Voltages
    110V (1A) -220V (0.6A)
    Power Supply
    AC220V±10%
    Current source
    AC/DC voltage source, AC/DC current source
    Power supply
    AC220V±10% 50Hz
    Maximum output power per phase
    420VA
    DC current output
    0- ± 10A/phase, accuracy: 0.5% ± 5mA
    Line voltage output (effective value)
    0-240V
    Three-phase parallel output
    0-90A
    Switching input terminal
    8 pairs
    Time range
    1ms -9999s
    Measurement accuracy
    1ms